Vendor support

Back Up and Recover the Code Running Your OT Stack

Copia brings version control, change visibility, and backup and recovery to 160+ integrations across Rockwell Automation, Siemens, Omron, Schneider Electric, and more.

Copia device view for the Durham, NC plant: 128 devices across 6 vendors (Rockwell, Siemens, Omron, Beckhoff, CODESYS and others), 100% backed up

Need an integration that isn’t listed?

Copia’s integration library is actively expanding. If your operation runs a vendor or version not listed here, let us know and we’ll follow up.

Request an integration

  • Schneider Electric
  • B&R
  • ABB
  • Rockwell Automation
  • Beckhoff
  • Siemens
  • Omron
  • WAGO
  • CODESYS

Every Supported Vendor, Device, and Version

Copia supports more than 160 integrations, counting each software version and device type separately, because support comes down to what’s actually on your network. Browse by vendor, device type, or version to confirm the devices you run are covered.

Vendor
Category
  • ABB

    Automation Builder

    PLCs and controllers

    Versions v2.5

    Backup method None (no device backup)

    • Supported:Version control (Native Git)
    • Supported:Graphical change rendering (Advanced Git)
    • Not supported:Backup & recovery (DeviceLink)
    Versions and details

    Supported versions

    • v2.5
  • ABB

    Drives (via NETA-21 module)

    Drives

    Versions All versions are compatible

    Backup method FTP

    • Supported:Version control (Native Git)
    • Not supported:Graphical change rendering (Advanced Git)
    • Supported:Backup & recovery (DeviceLink)
  • ABB

    IRC5 robot controller

    Robotics and CNC

    Versions RobotWare 6 (option 614-1 FTP)

    Backup method FTP

    • Supported:Version control (Native Git)
    • Not supported:Graphical change rendering (Advanced Git)
    • Supported:Backup & recovery (DeviceLink)
    Versions and details

    Supported versions

    • RobotWare 6 (option 614-1 FTP)
  • B&R

    Automation Studio

    PLCs and controllers

    Versions 4.11, 4.12

    Backup method None (no device backup)

    • Supported:Version control (Native Git)
    • Supported:Graphical change rendering (Advanced Git)
    • Not supported:Backup & recovery (DeviceLink)
    Versions and details

    Supported versions

    • 4.11
    • 4.12
  • Beckhoff

    TwinCAT

    PLCs and controllers

    Versions 3 (Build 3.1.4024.29+)

    Backup method Native

    • Supported:Version control (Native Git)
    • Supported:Graphical change rendering (Advanced Git)
    • Supported:Backup & recovery (DeviceLink)
    Versions and details

    Supported versions

    • 3 (Build 3.1.4024.29+)
  • Cisco

    Catalyst / IE switches and routers

    Network devices

    Versions IOS / IOS XE

    Backup method Scripting

    • Supported:Version control (Native Git)
    • Not supported:Graphical change rendering (Advanced Git)
    • Supported:Backup & recovery (DeviceLink)
    Versions and details

    Supported versions

    • IOS / IOS XE
  • CODESYS

    CODESYS

    PLCs and controllers

    Versions 11 supported (earliest 3.5 SP11, latest 3.5 SP21)

    Backup method Native

    • Supported:Version control (Native Git)
    • Supported:Graphical change rendering (Advanced Git)
    • Supported:Backup & recovery (DeviceLink)
    Versions and details

    Supported versions

    • 3.5 SP11
    • 3.5 SP12
    • 3.5 SP13
    • 3.5 SP14
    • 3.5 SP15
    • 3.5 SP16
    • 3.5 SP17
    • 3.5 SP18
    • 3.5 SP19
    • 3.5 SP20
    • 3.5 SP21
  • Cognex

    DataMan barcode readers (DataMan Setup Tool)

    Vision and barcode

    Versions DataMan series

    Backup method Scripting

    • Supported:Version control (Native Git)
    • Not supported:Graphical change rendering (Advanced Git)
    • Supported:Backup & recovery (DeviceLink)
    Versions and details

    Supported versions

    • DataMan series
  • Cognex

    In-Sight vision systems

    Vision and barcode

    Versions All versions are compatible

    Backup method FTP

    • Supported:Version control (Native Git)
    • Not supported:Graphical change rendering (Advanced Git)
    • Supported:Backup & recovery (DeviceLink)
  • FANUC

    CNC

    Robotics and CNC

    Versions All versions are compatible

    Backup method Scripting

    • Supported:Version control (Native Git)
    • Not supported:Graphical change rendering (Advanced Git)
    • Supported:Backup & recovery (DeviceLink)
  • FANUC

    Robots

    Robotics and CNC

    Versions All versions are compatible

    Backup method Native

    • Supported:Version control (Native Git)
    • Not supported:Graphical change rendering (Advanced Git)
    • Supported:Backup & recovery (DeviceLink)
  • Festo

    Automation Suite w/ CODESYS Extension

    PLCs and controllers

    Versions V2.8.0, V2.9.0, V2.10.0

    Backup method None (no device backup)

    • Supported:Version control (Native Git)
    • Supported:Graphical change rendering (Advanced Git)
    • Not supported:Backup & recovery (DeviceLink)
    Versions and details

    Supported versions

    • V2.8.0
    • V2.9.0
    • V2.10.0
  • GE

    iFIX HMI/SCADA

    HMI/SCADA

    Versions All versions are compatible

    Backup method Scripting

    • Supported:Version control (Native Git)
    • Not supported:Graphical change rendering (Advanced Git)
    • Supported:Backup & recovery (DeviceLink)
  • Inductive Automation

    Ignition

    HMI/SCADA

    Versions 8.0, 8.1, 8.3

    Backup method Scripting

    • Supported:Version control (Native Git)
    • Supported:Graphical change rendering (Advanced Git)
    • Supported:Backup & recovery (DeviceLink)
    Versions and details

    Supported versions

    • 8.0
    • 8.1
    • 8.3
  • Keyence

    SR-750 barcode reader (AutoID Network Navigator)

    Vision and barcode

    Versions SR-750

    Backup method FTP

    • Supported:Version control (Native Git)
    • Not supported:Graphical change rendering (Advanced Git)
    • Supported:Backup & recovery (DeviceLink)
    Versions and details

    Supported versions

    • SR-750
  • Keyence

    XG-X vision systems

    Vision and barcode

    Versions All versions are compatible

    Backup method FTP

    • Supported:Version control (Native Git)
    • Not supported:Graphical change rendering (Advanced Git)
    • Supported:Backup & recovery (DeviceLink)
  • KUKA

    KR C4 robot controller

    Robotics and CNC

    Versions KSS 8.3 and later

    Backup method Scripting

    • Supported:Version control (Native Git)
    • Not supported:Graphical change rendering (Advanced Git)
    • Supported:Backup & recovery (DeviceLink)
    Versions and details

    Supported versions

    • KSS 8.3 and later
  • Lenze

    PLC Designer

    PLCs and controllers

    Versions V3, V4

    Backup method None (no device backup)

    • Supported:Version control (Native Git)
    • Supported:Graphical change rendering (Advanced Git)
    • Not supported:Backup & recovery (DeviceLink)
    Versions and details

    Supported versions

    • V3
    • V4
  • Omron

    Sysmac Studio

    PLCs and controllers

    Versions 30 supported (earliest V1.26, latest V1.64)

    Backup method Native

    • Supported:Version control (Native Git)
    • Supported:Graphical change rendering (Advanced Git)
    • Supported:Backup & recovery (DeviceLink)
    Versions and details

    Supported versions

    • V1.26
    • V1.27
    • V1.28
    • V1.29
    • V1.30
    • V1.31
    • V1.40
    • V1.41
    • V1.42
    • V1.43
    • V1.44
    • V1.45
    • V1.46
    • V1.47
    • V1.48
    • V1.49
    • V1.50
    • V1.52
    • V1.53
    • V1.54
    • V1.55
    • V1.56
    • V1.57
    • V1.58
    • V1.59
    • V1.60
    • V1.61
    • V1.62
    • V1.63
    • V1.64
  • Rockwell

    FactoryTalk View SE

    HMI/SCADA

    Versions 5 supported (earliest V12, latest V16)

    Backup method sFTP

    • Supported:Version control (Native Git)
    • Not supported:Graphical change rendering (Advanced Git)
    • Supported:Backup & recovery (DeviceLink)
    Versions and details

    Supported versions

    • V12
    • V13
    • V14
    • V15
    • V16
  • Rockwell

    PanelView Plus 6 / 7 HMIs

    HMI/SCADA

    Versions V12, V13

    Backup method Native

    • Supported:Version control (Native Git)
    • Supported:Graphical change rendering (Advanced Git)
    • Supported:Backup & recovery (DeviceLink)
    Versions and details

    Supported versions

    • V12
    • V13
  • Rockwell

    PanelView Plus 6, 700 to 1500

    HMI/SCADA

    Versions 6 supported (earliest v6, latest v11)

    Backup method Native

    • Supported:Version control (Native Git)
    • Supported:Graphical change rendering (Advanced Git)
    • Supported:Backup & recovery (DeviceLink)

    Needs FactoryTalk View ME and the FactoryTalk View ME Transfer Utility v12 to v15 on the backup PC.

    Versions and details

    Supported versions

    • v6
    • v7
    • v8
    • v9
    • v10
    • v11
  • Rockwell

    PanelView Plus 7 Performance

    HMI/SCADA

    Versions 8 supported (earliest v8, latest v15)

    Backup method Native

    • Supported:Version control (Native Git)
    • Supported:Graphical change rendering (Advanced Git)
    • Supported:Backup & recovery (DeviceLink)

    Needs FactoryTalk View ME and the FactoryTalk View ME Transfer Utility v12 to v15 on the backup PC.

    Versions and details

    Supported versions

    • v8
    • v9
    • v10
    • v11
    • v12
    • v13
    • v14
    • v15
  • Rockwell

    PanelView Plus 7 Standard

    HMI/SCADA

    Versions 8 supported (earliest v8, latest v15)

    Backup method Native

    • Supported:Version control (Native Git)
    • Supported:Graphical change rendering (Advanced Git)
    • Some versions:Backup & recovery (DeviceLink)

    Needs FactoryTalk View ME and the FactoryTalk View ME Transfer Utility v12 to v15 on the backup PC.

    Backup & recovery covers v8 to v13.

    Versions and details

    Version control, graphical change rendering and backup & recovery

    • v8
    • v9
    • v10
    • v11
    • v12
    • v13

    Version control and graphical change rendering

    • v14
    • v15
  • Rockwell

    RSLogix 500

    PLCs and controllers

    Versions 5 supported (earliest v8, latest v12)

    Backup method Native

    • Supported:Version control (Native Git)
    • Supported:Graphical change rendering (Advanced Git)
    • Supported:Backup & recovery (DeviceLink)
    Versions and details

    Supported versions

    • v8
    • v9
    • v10
    • v11
    • v12
  • Rockwell

    RSLogix 5000

    PLCs and controllers

    Versions 5 supported (earliest v16, latest v20)

    Backup method Native

    • Supported:Version control (Native Git)
    • Supported:Graphical change rendering (Advanced Git)
    • Supported:Backup & recovery (DeviceLink)
    Versions and details

    Supported versions

    • v16
    • v17
    • v18
    • v19
    • v20
  • Rockwell

    Stratix switches

    Network devices

    Versions All versions are compatible

    Backup method Scripting

    • Supported:Version control (Native Git)
    • Not supported:Graphical change rendering (Advanced Git)
    • Supported:Backup & recovery (DeviceLink)
  • Rockwell

    Studio 5000 Logix Designer

    PLCs and controllers

    Versions 15 supported (earliest v21, latest v38)

    Backup method Native

    • Supported:Version control (Native Git)
    • Supported:Graphical change rendering (Advanced Git)
    • Supported:Backup & recovery (DeviceLink)
    Versions and details

    Supported versions

    • v21
    • v24
    • v26
    • v27
    • v28
    • v29
    • v30
    • v31
    • v32
    • v33
    • v34
    • v35
    • v36
    • v37
    • v38
  • Schneider

    Control Expert (Classic)

    PLCs and controllers

    Versions 8 supported (earliest V14.1, latest V16.2)

    Backup method Native

    • Supported:Version control (Native Git)
    • Supported:Graphical change rendering (Advanced Git)
    • Supported:Backup & recovery (DeviceLink)
    Versions and details

    Supported versions

    • V14.1
    • V15.0 (incl. SP1)
    • V15.1
    • V15.2
    • V15.3
    • V16.0
    • V16.1
    • V16.2
  • Schneider

    EcoStruxure Machine Expert

    PLCs and controllers

    Versions 9 supported (earliest V2.0.1, latest V2.2.2)

    Backup method None (no device backup)

    • Supported:Version control (Native Git)
    • Supported:Graphical change rendering (Advanced Git)
    • Not supported:Backup & recovery (DeviceLink)
    Versions and details

    Supported versions

    • V2.0.1
    • V2.0.2
    • V2.0.3
    • V2.1
    • V2.1.1
    • V2.1.2
    • V2.2
    • V2.2.1
    • V2.2.2
  • Schneider

    Unity Pro

    PLCs and controllers

    Versions v13

    Backup method Native

    • Supported:Version control (Native Git)
    • Supported:Graphical change rendering (Advanced Git)
    • Supported:Backup & recovery (DeviceLink)
    Versions and details

    Supported versions

    • v13
  • Siemens

    SCALANCE switches

    Network devices

    Switch families 9 (W, X-200, X-300, X-400, XB, XC, XM, XP, XR)

    Backup method Native

    • Supported:Version control (Native Git)
    • Not supported:Graphical change rendering (Advanced Git)
    • Supported:Backup & recovery (DeviceLink)
    Versions and details

    Supported switch families

    • W
    • X-200
    • X-300
    • X-400
    • XB
    • XC
    • XM
    • XP
    • XR
  • Siemens

    Step7

    PLCs and controllers

    Versions 5 supported (earliest V5.6 SP2, latest V5.7 SP3)

    Backup method Native

    • Supported:Version control (Native Git)
    • Supported:Graphical change rendering (Advanced Git)
    • Supported:Backup & recovery (DeviceLink)
    Versions and details

    Supported versions

    • V5.6 SP2
    • V5.7
    • V5.7 SP1
    • V5.7 SP2
    • V5.7 SP3
  • Siemens

    Step7 TIA Portal

    PLCs and controllers

    Versions 9 supported (earliest V14 SP1, latest V21)

    Backup method Native

    • Supported:Version control (Native Git)
    • Supported:Graphical change rendering (Advanced Git)
    • Some versions:Backup & recovery (DeviceLink)

    Backup & recovery covers V15.1 to V21.

    Versions and details

    Version control and graphical change rendering

    • V14 SP1
    • V15

    Version control, graphical change rendering and backup & recovery

    • V15.1
    • V16
    • V17
    • V18
    • V19
    • V20
    • V21
  • Wago

    CODESYS

    PLCs and controllers

    Versions 3.5

    Backup method Native

    • Supported:Version control (Native Git)
    • Supported:Graphical change rendering (Advanced Git)
    • Supported:Backup & recovery (DeviceLink)
    Versions and details

    Supported versions

    • 3.5
  • Wago

    e!COCKPIT

    PLCs and controllers

    Versions v1.10

    Backup method None (no device backup)

    • Supported:Version control (Native Git)
    • Supported:Graphical change rendering (Advanced Git)
    • Not supported:Backup & recovery (DeviceLink)
    Versions and details

    Supported versions

    • v1.10
  • Custom/Generic

    Generic devices

    Generic protocols

    Covers any device that backs up over FTP, sFTP or SCP, or with a script

    Backup method FTP, sFTP, SCP, Scripting

    • Supported:Version control (Native Git)
    • Not supported:Graphical change rendering (Advanced Git)
    • Supported:Backup & recovery (DeviceLink)
    Versions and details

    Supported methods

    • FTP
    • sFTP
    • SCP
    • Scripting

Don’t See Your Tool?

We add integrations based on what customers run. Tell us your vendor, software, and version, and we’ll follow up.

Take the Next Step To Build Your Operational Resilience